内置循环系统高仿真小儿静脉输液手臂的制作及教学应用
The Production and Teaching Application of the Internal Circulation System in the high Simulation of Pediatric Intravenous Transfusion Arm
-
摘要: 目的 设计制作内置循环系统高仿真小儿静脉输液手臂,比较传统模型教学法与内置循环系统高仿真小儿静脉输液手臂模型教学法教学效果的差异性.方法 以昆明学院100名2013级本科护理学专业的学生为研究对象,采取小儿静脉输液手臂模型教学法为研究组,传统模型教学法为对照组,比较2组实践技能考核成绩和教学成本的差异.结果 与对照组比较,研究组实践技能考核成绩(87.8±6.9)分高于对照组(78.5±7.4)分(P<0.05);与对照组比较,研究组教学成本(2.64±0.4)元高于对照组(12.89±0.6)元,P<0.05;与对照组比较,研究组穿刺成功率82.8%高于对照组62.3%(P<0.05).结论 内置循环系统高仿真小儿静脉输液手臂模型教学法在基础护理学实践技能教学中可明显提高教学效果,能明显提高学生教学目标的达标率,可以有效调动学生学习积极性.Abstract: Objective To compare the difference between traditional model teaching method and the system of internal circulation system with high simulation of the teaching method of the teaching method of the arm of the arm of the intravenous infusion in children.Methods The research objects were taken as the research object, and the model of the arm of the 2013 students in Kunming college was taken as the research object,and the traditional model was the control group. The difference between the two groups were compared between the 100 groups.Results Compared with the control group,the study group's practice skill score(87.8 ± 6.9) points was higher than that in the control group(78.5 ± 7.4)(P <0.05);the teaching cost(2.64 ± 0.4 yuan) was higher than that in the control group(12.89±0.6 yuan)(P <0.05);the success rate of puncture in the study group 82.8% was higher than that in the control group(62.3%)(P <0.05).Conclusion The internal circulation system of high simulation of pediatric intravenous infusion arm model teaching method in basic nursing practice teaching can improve the teaching effect,the students teaching goal,and mobilize the enthusiasm of students learning.
-
[1]张亚敏.临床护理路径干预在小儿输液中的应用效果[J].国际护理学杂志,2015,8(8):1042-1044. [2]林静娟,王小蕾.临床护理路径干预在小儿输液60例中的应用[J].中国民族民间医药杂志,2015,24(12):129. [3]沈艳红,赵线,万红.优质护理服务在小儿输液室的应用效果[J].实用临床医学,2016,17(1):55-57. [4]梁丽芳,龚要玲.完全植入式静脉输液港在血液肿瘤患儿中的应用和护理[J].护理实践与研究,2016,13(7):114-115. [5]邢琳娜.静脉留置针在门诊静脉输液中的应用及护理效果分析[J].中国医药指南,2016,14(12):247. [6]陈云宏.护理风险管理在小儿头皮静脉输液中的应用效果观察[J].生物技术世界,2016,(3):169-170. [7]苏瑜,李莉,陈芳,等.护理风险管理在小儿头皮静脉输液中的临床应用效果[J].检验医学与临床,2016,13(3):402-403. [8]吴秀仙,叶昌华,饶和平.国产与进口静脉输液手臂模型使用成本比较[J].护理研究,2007,21(12):3287-3288. [9]吴秀仙,叶昌华,饶和平,等.不同注射方法、针头及注水对静脉输液手臂模型寿命的影响[J].护理研究,2008,22(8):2142-2143. [10]张大新,余珊,荣桦,等.全功能高仿真静脉输液手臂制作及教学应用[J].卫生职业教育,2011,29(21):102-103. [11]何文丽,梦金娥.门诊小儿输液护患纠纷原因分析和对策[J].当代护士,2014,2(1):28-29. [12]李亚梅.小儿静脉输液的体会[J].中国伤残医学,2014,22(1):238-239. [13]龚梅,患者对实习护生进行静脉输液的态度调查。护理研究,2007,21(7):182.
点击查看大图
计量
- 文章访问数: 1458
- HTML全文浏览量: 538
- PDF下载量: 34
- 被引次数: 0