留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

上下颌轻中度拥挤下iTero Element 1口扫数字化模型的准确性

肖倩 周锟 王蕾 高俊 陈俊润 任娅岚

肖倩, 周锟, 王蕾, 高俊, 陈俊润, 任娅岚. 上下颌轻中度拥挤下iTero Element 1口扫数字化模型的准确性[J]. 昆明医科大学学报, 2023, 44(10): 149-154. doi: 10.12259/j.issn.2095-610X.S20231025
引用本文: 肖倩, 周锟, 王蕾, 高俊, 陈俊润, 任娅岚. 上下颌轻中度拥挤下iTero Element 1口扫数字化模型的准确性[J]. 昆明医科大学学报, 2023, 44(10): 149-154. doi: 10.12259/j.issn.2095-610X.S20231025
Qian XIAO, Kun ZHOU, Lei WANG, Jun GAO, Junrun CHEN, Yalan REN. Accuracy of iTero Element 1 Intraoral Scanner Digital Model in Mild to Moderate Crowding of the Maxillary and Mandibular Arch[J]. Journal of Kunming Medical University, 2023, 44(10): 149-154. doi: 10.12259/j.issn.2095-610X.S20231025
Citation: Qian XIAO, Kun ZHOU, Lei WANG, Jun GAO, Junrun CHEN, Yalan REN. Accuracy of iTero Element 1 Intraoral Scanner Digital Model in Mild to Moderate Crowding of the Maxillary and Mandibular Arch[J]. Journal of Kunming Medical University, 2023, 44(10): 149-154. doi: 10.12259/j.issn.2095-610X.S20231025

上下颌轻中度拥挤下iTero Element 1口扫数字化模型的准确性

doi: 10.12259/j.issn.2095-610X.S20231025
基金项目: 云南省口腔疾病临床医学研究中心青年科研基金资助项目(2022QN006);昆明医科大学大学生创新基金资助项目(2022JXD196)
详细信息
    作者简介:

    肖倩(2002~),女,云南曲靖人,在读本科生,主要从事口腔医学研究工作

    周锟与肖倩对本文有同等贡献

    任娅岚,主治医师, 2014年毕业于昆明医科大学,获口腔正畸学硕士学位,现就职于昆明医科大学附属口腔医院,擅长青少年早期矫治,成人固定矫治和数字化隐形矫治。中华口腔医学会会员,中华口腔正畸专委会会员,云南省正畸专委会青年委员,云南省医学会数字医学分会青年委员,2016年中国Tweed中心第二届经典方丝弓弯制大赛全国二十五强,2017年“西部盛会,隐领风骚”透明牙套隐形矫治病例大赛全国八强,2021年第二十六次全国儿科学会口腔病例大赛三等奖。主要从事牙周膜干细胞成骨和免疫相关研究以及数字化正畸临床研究。获得实用新型专利技术1项,主持临床新技术1项,主持校级课题2项,主持院内课题1项,参与国家级课题2项,核心期刊发表论文4篇

    通讯作者:

    任娅岚,E-mail:670312366@qq.com

  • 中图分类号: R783.5

Accuracy of iTero Element 1 Intraoral Scanner Digital Model in Mild to Moderate Crowding of the Maxillary and Mandibular Arch

  • 摘要:   目的  评估轻中度拥挤下采用iTero Element 1口内扫描仪获得的数字化模型和传统石膏模型测量数据的准确性。  方法  选取到昆明医科大学附属口腔医院前兴路门诊部就诊的37名患者,使用iTero Element 1口内扫描仪扫描获得数字化模型和藻酸盐取模获得同一患者传统石膏模型,比较数字化模型自动测量和传统石膏模型人工测量牙冠宽度、牙弓宽度、覆盖的差异。  结果  数字化模型和石膏模型的3次重复测量一致性检验ICC值均在0.9以上,均具有良好的可重复性。轻度拥挤组11、16、21、31、36、41、43、46牙冠宽度、14~24牙弓宽度、22覆盖,中度拥挤组11、23、16、31牙冠宽度、14~24牙弓宽度、11、12覆盖差异有统计学意义(P < 0.05)。  结论  iTero数字化模型在轻中度拥挤时部分数据与手工测量石膏模型存在一定差异,可能是由于牙齿排列不齐,导致测量误差,但测量数据差异较小,不影响iTero数字化模型在临床中的应用。
  • 表  1  石膏模型和数字化模型3次重复测量牙冠宽度的ICC值

    Table  1.   The ICC value of the three repeated measurements consistency tests of the digital model and plaster model

    测量项目石膏模型测量ICC值数字化测量ICC值
    11牙冠宽度 0.946 0.986
    12牙冠宽度 0.972 0.982
    13牙冠宽度 0.954 0.962
    14牙冠宽度 0.963 0.966
    15牙冠宽度 0.994 0.962
    16牙冠宽度 0.957 0.950
    21牙冠宽度 0.973 0.991
    22牙冠宽度 0.980 0.993
    23牙冠宽度 0.940 0.972
    24牙冠宽度 0.972 0.936
    25牙冠宽度 0.991 0.984
    26牙冠宽度 0.910 0.969
    31牙冠宽度 0.954 0.945
    32牙冠宽度 0.958 0.956
    33牙冠宽度 0.950 0.977
    34牙冠宽度 0.972 0.952
    35牙冠宽度 0.994 0.990
    36牙冠宽度 0.937 0.969
    41牙冠宽度 0.933 0.942
    42牙冠宽度 0.921 0.926
    43牙冠宽度 0.982 0.978
    44牙冠宽度 0.957 0.964
    45牙冠宽度 0.991 0.991
    46牙冠宽度 0.982 0.976
    下载: 导出CSV

    表  2  上颌牙列轻中度拥挤下石膏模型测量和iTero Element 1测量牙冠宽度差值(mm,$\bar x \pm s $

    Table  2.   Difference of crown width measured by plaster model and iTero Element 1 under mild and moderate crowding in maxillary dentition (mm,$\bar x \pm s $

    牙位轻度拥挤组(n = 17)tP中度拥挤组(n = 8)tP
    11 0.125 ± 0.205 2.523 0.023* 0.176 ± 0.180 2.768 0.028*
    12 0.039 ± 0.214 0.749 0.465 0.125 ± 0.203 1.740 0.125
    13 −0.001 ± 0.250 −0.010 0.992 −0.048 ± 0.089 −1.514 0.174
    14 0.030 ± 0.432 0.286 0.778 −0.066 ± 0.319 −0.587 0.575
    15 0.350 ± 0.770 1.435 0.170 0.070 ± 0.240 1.111 0.303
    16 −0.488 ± 0.554 −3.631 0.002* −0.470 ± 0.310 −2.392 0.048*
    21 0.095 ± 0.175 2.251 0.039* 0.250 ± 0.240 1.890 0.101
    22 −0.020 ± 0.268 −0.308 0.762 0.115 ± 0.272 1.195 0.271
    23 0.074 ± 0.219 1.392 0.183 0.141 ± 0.164 2.440 0.045*
    24 0.186 ± 0.530 1.452 0.166 0.096 ± 0.489 0.557 0.595
    25 0.060 ± 0.730 0.239 0.814 −0.139 ± 0.276 −1.423 0.198
    26 −0.471 ± 0.386 −5.035 < 0.001* −0.221 ± 0.313 −1.999 0.086
      *P < 0.05。
    下载: 导出CSV

    表  3  下颌牙列轻中度拥挤下石膏模型测量和iTero Element 1测量牙冠宽度差值(mm,$\bar x \pm s $

    Table  3.   Difference of crown width measured by plaster model and iTero Element 1 under mild and moderate crowding in mandibular dentition (mm,$\bar x \pm s $

    牙位轻度拥挤组(n = 16)tP中度拥挤组(n = 10)tP
    31 0.180 ± 0.180 3.367 0.004* 0.210 ± 0.310 1.908 0.089
    32 0.020 ± 0.280 1.248 0.231 0.150 ± 0.220 1.751 0.114
    33 0.030 ± 0.230 0.103 0.920 0.260 ± 0.140 1.126 0.289
    34 0.010 ± 0.200 −0.425 0.677 0.040 ± 0.215 0.589 0.570
    35 0.033 ± 0.391 0.339 0.739 −0.033 ± 0.125 −0.834 0.426
    36 −0.202 ± 0.252 −2.996 0.010* −0.170 ± 0.200 −2.692 0.025*
    41 0.176 ± 0.279 2.519 0.024* 0.046 ± 0.240 0.605 0.560
    42 0.210 ± 0.330 2.957 0.010* 0.084 ± 0.367 0.725 0.487
    43 0.010 ± 0.180 2.166 0.047* 0.153 ± 0.298 1.626 0.138
    44 0.004 ± 0.293 0.060 0.953 0.049 ± 0.246 0.630 0.545
    45 0.100 ± 0.250 0.247 0.808 0.051 ± 0.200 0.807 0.440
    46 −0.140 ± 0.206 −2.454 0.030* −0.266 ± 0.391 −2.038 0.076
      *P < 0.05。
    下载: 导出CSV

    表  4  上颌牙轻中度拥挤下石膏模型测量和iTero Element 1测量牙弓宽度差值(mm,$\bar x \pm s $

    Table  4.   Difference of arch width measured by plaster model and iTero Element 1 under mild and moderate crowding in maxillary dentition (mm,$\bar x \pm s $

    牙弓宽度轻度拥挤组tP中度拥挤组tP
    13~23 0.138 ± 1.567 0.351 0.730 −0.850 ± 1.378 −1.744 0.125
    14~24 −0.920 ± 0.900 −3.086 0.008* −0.690 ± 0.680 −2.615 0.040*
    15~25 −1.393 ± 1.612 −3.234 0.007* −0.490 ± 0.440 −1.236 0.271
    16~26 −0.220 ± 0.832 −1.024 0.323 0.100 ± 0.590 −0.894 0.401
      *P < 0.05。
    下载: 导出CSV

    表  5  下颌牙轻中度拥挤下石膏模型测量和iTero Element 1测量牙弓宽度差值(d牙弓宽度)(mm,$\bar x \pm s $

    Table  5.   Difference of arch width measured by plaster model and iTero Element 1 under mild and moderate crowding in mandibular dentition (mm,$\bar x \pm s $

    牙弓宽度轻度拥挤组tP中度拥挤组tP
    33~34 −0.188 ± 1.074 −0.698 0.496 −0.310 ± 0.470 −2.085 0.067
    34~44 −0.380 ± 1.270 −4.172 < 0.001* −0.513 ± 1.089 −1.331 0.225
    35~45 −0.540 ± 1.680 −1.796 0.093 −0.090 ± 0.824 −0.345 0.738
    36~46 −1.360 ± 1.106 −4.764 < 0.001* −0.490 ± 0.550 −0.150 0.884
      *P < 0.05。
    下载: 导出CSV

    表  6  轻中度拥挤下石膏模型测量和iTero Element 1测量覆盖差值(d覆盖)(mm,$\bar x \pm s $

    Table  6.   Difference of arch width measured by plaster model and iTero Element 1 under mild and moderate crowding in mandibular dentition (mm,$\bar x \pm s $

    牙位轻度拥挤组(n = 17)tP中度拥挤组(n = 8)tP
    11 −0.550 ± 0.660 −1.245 0.231 −0.488 ± 0.490 −2.806 0.026*
    12 −0.440 ± 0.710 −1.692 0.109 −0.550 ± 0.644 −2.413 0.046*
    21 −0.570 ± 0.730 −1.017 0.324 −0.463 ± 0.741 −1.758 0.121
    22 −0.610 ± 0.620 −3.637 0.002* −0.258 ± 0.768 −0.950 0.373
      *P < 0.05。
    下载: 导出CSV
  • [1] 赵志河主编. 口腔正畸学[M]. 第7版. 北京: 北京人民卫生出版社, 2020: 54-172.
    [2] Su T S,Shu J. Intraoral digital impression technique: A review[J]. J Prosthodont,2015,24(4):313-321. doi: 10.1111/jopr.12218
    [3] 葛峻沂,王佩佩,周鹏,等. iTero口腔数字化扫描软件在口腔正畸教学中的应用探索[J]. 科教导刊,2023,(12):88-90.
    [4] 程明轩,姜婷,孙玉春,等. 比较口内扫描和模型扫描对数字化牙列模型咬合定量分析的影响[J]. 北京大学学报(医学版),2018,50(1):136-140.
    [5] 游恺,张宁. 五种口内扫描仪模型扫描精度对比及扫描质量评估[J]. 口腔颌面修复学杂志,2023,24(4):259-265.
    [6] 郑小婉,刘金平,黄晓峰. 轻重度拥挤正畸模型手工测量和数字化测量的可靠性评价研究[J]. 临床口腔医学杂志,2021,37(7):395-399.
    [7] 游恺,张宁. 三种口内扫描仪精度的对比研究[J]. 口腔颌面修复学杂志,2023,24(2):87-92.
    [8] 张晖榕,尹乐锋,刘艳丽,等. 基于锥形术CT数字化建模的3D打印牙颌模型制作及精确度研究[J]. 华西口腔医学杂志,2018,36(2):156-161.
    [9] Kravitz N D,Groth C,Jones P E,et al. Intraoral digital scanners[J]. J Clin Orthod,2014,48(6):337-347.
    [10] Flugge T V,Schlager S,Nelson K,et al. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner[J]. Am J Orthod Dentofacial Orthop,2013,144(3):471-478. doi: 10.1016/j.ajodo.2013.04.017
    [11] Zhang F,Suh K J,Lee K M. Validity of intraoral scans compared with plaster models: An in-vivo comparison of dental measurements and 3D surface analysis[J]. PLoS One,2016,11(6):e157713.
    [12] Leifert M F,Leifert M M,Efstratiadis S S,et al. Comparison of space analysis evaluations with digital models and plaster dental casts[J]. Am J Orthod Dentofacial Orthop,2009,136(1):16.e1-16. doi: 10.1016/j.ajodo.2009.05.002
    [13] 杨雷宁,韩晓鹏,张萌萌,等. 牙颌数字化模型与石膏模型在线距和角度测量方面的准确性研究[J]. 口腔医学研究,2019,35(8):802-805.
    [14] 刘静. 口内扫描仪全牙列扫描精度及不同操作者间扫描精度差异的研究[D]. 济南: 山东大学, 2017.
    [15] Su T S,Sun J. Comparison of repeatability between intraoral digital scanner and extraoral digital scanner:An in-vitro study[J]. Journal of Prosthodontic Research,2015,59(4):236-242.
    [16] Liang Y M,Rutchakitprakarn L,Kuang S H,et al. Comparing the reliability and accuracy of clinical measurements using plaster model and the digital model system based on crowding severity[J]. J Chin Med Assoc,2018,81(9):842-847. doi: 10.1016/j.jcma.2017.11.011
    [17] 谢轶伦,沈刚. 全口牙列口内扫描的精确性与可重复性分析[J]. 上海口腔医学,2016,25(5):593-599.
    [18] Kim J,Heo G,Lagravere M O. Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography[J]. Angle Orthod,2014,84(3):443-450. doi: 10.2319/051213-365.1
    [19] Luu N S,Nikolcheva L G,Retrouvey J M,et al. Linear measurements using virtual study models[J]. Angle Orthod,2012,82(6):1098-1106. doi: 10.2319/110311-681.1
    [20] Asquith J,Gillgrass T,Mossey P. Three-dimensional imaging of orthodontic models: A pilot study[J]. Eur J Orthod,2007,29(5):517-522. doi: 10.1093/ejo/cjm044
    [21] Santoro M,Galkin S,Teredesai M,et al. Comparison of measurements made on digital and plaster models[J]. Am J Orthod Dentofacial Orthop,2003,124(1):101-105. doi: 10.1016/S0889-5406(03)00152-5
    [22] McCann J,Burden D J. An investigation of tooth size in Northern Irish people with bimaxillary dental protrusion[J]. Eur J Orthod,1996,18(6):617-621. doi: 10.1093/ejo/18.6.617
    [23] Yuzbasioglu E,Kurt H,Turunc R,et al. Comparison of digital and conventional impression techniques: evaluation of patients’ perception,treatment comfort,effectiveness and clinical outcomes[J]. BMC Oral Health,2014,14:10. doi: 10.1186/1472-6831-14-10
  • [1] 周静, 陈丽琼, 冯雯娟, 吴长云, 孙素, 李昌全, 王荃.  口腔数字化定位体系结合CBL教学方法在正畸托槽定位粘接教学中的应用, 昆明医科大学学报. doi: 10.12259/j.issn.2095-610X.S20230127
    [2] 季娟娟, 刘亚丽, 周治, 许艳华, 朱亚玲, 王睿.  数字化技术对上颌唇向低位尖牙矫治的干预, 昆明医科大学学报. doi: 10.12259/j.issn.2095-610X.S20230923
    [3] 李霞, 王晋.  数字乳腺断层摄影(DBT)与全数字化乳腺摄影(FFDM)对乳腺病变诊断效能的对比, 昆明医科大学学报. doi: 10.12259/j.issn.2095-610X.S20220914
    [4] 解琴, 梁艳平, 张引, 徐增辉, 尤丽英.  多种无创诊断模型诊断慢性肝病患者肝纤维化的效能, 昆明医科大学学报. doi: 10.12259/j.issn.2095-610X.S20210719
    [5] 杨紫嫣, 李星星, 林云红.  无牙颌患者数字化方法制作全口义齿的临床疗效, 昆明医科大学学报. doi: 10.12259/j.issn.2095-610X.S20210322
    [6] 董苑, 李彩霞, 赵娴, 驼晓宇, 刘流, 马芸.  小鼠股骨缺损模型的构建及SDF-1表达的检测, 昆明医科大学学报.
    [7] 檀雅欣, 李珊, 王廷华, 习杨彦彬.  APP/PS1+SCN2B-/-转基因小鼠模型的建立及鉴定, 昆明医科大学学报.
    [8] 李俊满, 钱捷, 殷毅, 彭艺, 税艳青, 杨春, 胡瑜, 杨禾丰.  利用数字化技术分析口腔医学生牙体预备聚合度情况, 昆明医科大学学报.
    [9] 侯云鹤, 张皓鑫, 王依雨, 苏艳梅, 顾丹珊, 林少芳, 杨世昆, 李树德.  人参皂苷Rg1对NAFLD动物模型中同型半胱氨酸的调控机制, 昆明医科大学学报.
    [10] 钱程, 司敬琅, 唐波, 肖曙峰, 付必莽, 张捷.  树鼩肝移植模型的建立, 昆明医科大学学报.
    [11] 张柽.  猪体外并行循环模型的建立及管理, 昆明医科大学学报.
    [12] 董昭兴.  IL-27在博来霉素诱导肺纤维化模型中的保护作用, 昆明医科大学学报.
    [13] 刘彦.  滇南小耳猪深Ⅱ度烧(烫)伤模型的建立, 昆明医科大学学报.
    [14] 李源.  人参皂苷Rg1对AD大鼠脑片模型Bcl-2表达的影响, 昆明医科大学学报.
    [15] 陈媛.  家兔高钾血症病理模型的建立, 昆明医科大学学报.
    [16] 陈郊丽.  糖尿病鼠模型研究新进展, 昆明医科大学学报.
    [17] 闫永吉.  肾上腺醛固酮腺瘤大鼠模型的建立, 昆明医科大学学报.
    [18] 贺斌.  数字化钼靶检查诊断乳腺浸润性导管癌, 昆明医科大学学报.
    [19] 人免疫重建NOD/SCID小鼠模型的建立, 昆明医科大学学报.
    [20] 王爱萍.  Ibotenate脑内注射诱导脑白质损伤的新生小鼠模型研究, 昆明医科大学学报.
  • 加载中
计量
  • 文章访问数:  1540
  • HTML全文浏览量:  924
  • PDF下载量:  21
  • 被引次数: 0
出版历程
  • 收稿日期:  2023-07-27
  • 网络出版日期:  2023-09-12
  • 刊出日期:  2023-10-25

目录

    /

    返回文章
    返回