Application Status of CAD/CAM in Prosthodontics
-
摘要: 近年来计算机辅助设计和制造(CAD/CAM)不断推动口腔领域的发展和改革。口腔修复是口腔医学的重要组成部分,CAD/CAM越来越多地运用于口腔修复,促使口腔修复飞速发展。通过总结多篇国内外文献,概述CAD/CAM在口腔修复中的应用进展。Abstract: In recent years, computer-aided design and manufacturing (CAD/CAM) have been driving the development and reform of the dental field. Prosthodontics is an essential part of oral medicine, and CAD/CAM is increasingly being used in prosthodontics, leading to rapid advancements in this field. This paper summarizes a number of domestic and international literatures to provide an overview of the progress of CAD/CAM in prosthodontics.
-
Key words:
- Compute aided design /
- Compute aided manufacturing /
- Prosthodontic
-
[1] Miyazaki T,Hotta Y,Kunii J,et al. A review of dental CAD/CAM: Current status and future perspectives from 20 years of experience[J]. Dent Mater J,2009,28(1):44-56. doi: 10.4012/dmj.28.44 [2] 黄清川,黄翠,蔡新杰. 数字化口内扫描技术在口腔修复学临床和教学中的应用[J]. 口腔颌面修复学杂志,2022,23(5):366-373. [3] Chi J. Digital impressions and in-office CAD/CAM: A review of best practices and what's to come[J]. Compend Contin Educ Dent,2021,42(3):140-141. [4] Fung L,Brisebois P. Implementing digital dentistry into your esthetic dental practice[J]. Dent Clin North Am,2020,64(4):645-657. doi: 10.1016/j.cden.2020.07.003 [5] Tanveer W,Ridwan-Pramana A,Molinero-Mourelle P,et al. Systematic review of clinical applications of CAD/CAM technology for craniofacial implants placement and manufacturing of orbital prostheses[J]. Int J Environ Res Public Health,2021,18(21):11349. doi: 10.3390/ijerph182111349 [6] Mühlemann S,Benic G I,Fehmer V,et al. Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic posterior fixed partial dentures. Part II: Time efficiency of CAD-CAM versus conventional laboratory procedures[J]. J Prosthet Dent,2019,121(2):252-257. doi: 10.1016/j.prosdent.2018.04.020 [7] Khan S,Ali A,Siddique R,et al. Novel coronavirus is putting the whole world on alert[J]. J Hosp Infect,2020,104(3):252-253. doi: 10.1016/j.jhin.2020.01.019 [8] Barenghi L,Barenghi A,Garagiola U,et al. Pros and Cons of CAD/CAM technology for infection prevention in dental settings during COVID-19 outbreak[J]. Sensors (Basel),2021,22(1):49. doi: 10.3390/s22010049 [9] Komine F,Honda J,Kusaba K,et al. Clinical outcomes of single crown restorations fabricated with resin-based CAD/CAM materials[J]. J Oral,2020,62(4):353-355. doi: 10.2334/josnusd.20-0195 [10] Krug R,Droste L,Schreiber C,et al. Long-term performance of ceramic in/-onlays vs. cast gold partial crowns - a retrospective clinical study[J]. Clin Oral Investig,2024,28(5):298. doi: 10.1007/s00784-024-05682-7 [11] Metiner C,Türker Ş B. Evaluation of clinical success and marginal adaptations of inlay and onlay restorations manufactured after conventional and digital impressions: A prospective randomized controlled clinical study[J]. Int J Comput Dent,2021,24(2):207-223. [12] Bustamante-Hernández N,Montiel-Company J M,Bellot-Arc í s C,et al. Clinical behavior of ceramic,hybrid and composite onlays. A systematic review and meta-analysis[J]. IntJ Environ Res Public Health,2020,17(20):7582. doi: 10.3390/ijerph17207582 [13] Vagropoulou G I,Klifopoulou G L,Vlahou S G,et al. Complications and survival rates of inlays and onlays vs complete coverage restorations: A systematic review and analysis of studies[J]. J Oral Rehabil,2018,45(11):903-920. doi: 10.1111/joor.12695 [14] Tunac A T,Celik E U,Yasa B. Two-year performance of CAD/CAM fabricated resin composite inlay restorations: A randomized controlled clinical trial[J]. J Esthet Restor Dent,2019,31(6):627-638. doi: 10.1111/jerd.12534 [15] Mandal N B,Kumari A,Baldev K C,et al. A clinical evaluation of onlay and inlay in the posterior ceramic restorations: An original study[J]. J Pharm Bioallied,2022,14(1):310-312. [16] 张锋娟,宋长钦. CAD/CAM高嵌体修复根管治疗后磨牙大面积缺损的临床应用[J]. 北京口腔医学,2021,29(6):370-373. [17] 刘方宇,朱加林,丁存善,等. CAD/CAM氧化锆髓超嵌体修复磨牙根管治疗后牙体缺损的临床效果评价[J]. 宁夏医科大学报,2021,43(1):52-56. [18] Arcuri L,Lorenzi C,Bianchi N,et al. Fit evaluation of cad/cam fabricated all-ceramic restorations based on direct and indirect digitalization in vivo: A systematic review[J]. J Biol Regul Homeost Agents,2019,33(3):103-111. [19] Khamverdi Z,Najafrad E,Farhadian M. In vitro comparison of marginal and internal fit of zirconia copings fabricated by one CAD/CAM system with two different scanners[J]. Front Dent,2021,20(1):18-21. [20] Scaringi R,Nannelli M,Franchina A,et al. Full zirconia implant-born prosthetic rehabilitation with CAD/CAM technology after accurate digital planning A Case Report[J]. Int J Environ Res Public Health,2021,18(15):7998. doi: 10.3390/ijerph18157998 [21] Rodrigues S B,Franken P,Celeste R K,et al. CAD/CAM or conventional ceramic materials restorations longevity: A systematic review and meta-analysis[J]. J Prosthodont Res,2019,63(4):389-395. doi: 10.1016/j.jpor.2018.11.006 [22] Aswal G S,Rawat R,Dwivedi D,et al. Clinical outcomes of CAD/CAM (Lithium disilicate and Zirconia) based and conventional full crowns and fixed partial dentures: A systematic review and meta-analysis[J]. Cureus,2023,15(4):e37888. [23] Hallmann L,Ulmer P,Wille S,et al. Effect of differences in coefficient of thermal expansion of veneer and Y-TZP ceramics on interface phase transformation[J]. J Prosthet Dent,2014,112(3):591-599. doi: 10.1016/j.prosdent.2013.11.009 [24] Kim J J. Revisiting the removable partial denture[J]. Dent Clin North Am,2019,63(2):263-278. doi: 10.1016/j.cden.2018.11.007 [25] Arnold C,Hey J,Schweyen R,et al. Accuracy of CAD-CAM-fabricated removable partial dentures[J]. J Prosthet Dent,2018,119(4):586-592. doi: 10.1016/j.prosdent.2017.04.017 [26] Maeda Y,Minoura M,Tsutsumi S,et al. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures[J]. Int J Prosthodont,1994,7(1):17-21. [27] Anadioti E,Musharbash L,Blatz MB,et al. 3D printed complete removable dental prostheses: A narrative review[J]. BMC Oral Health,2020,27;20(1):343. [28] Ahmed N,Abbasi M S,Haider S,et al. Fit accuracy of removable partial denture frameworks fabricated with CAD/CAM,rapid prototyping,and conventional techniques: A systematic review[J]. Biomed Res Int,2021,6(9):319433. [29] Arafa K A O. Assessment of the fit of removable partial denture fabricated by computer-aided designing/computer aided manufacturing technology[J]. Saudi Med J,2018,39(1):17-22. doi: 10.15537/smj.2018.1.20796 [30] Takaichi A,Fueki K,Murakami N,et al. A systematic review of digital removable partial dentures. Part II: CAD/CAM framework,artificial teeth,and denture base[J]. J Prosthodont Res,2022,66(1):53-67. doi: 10.2186/jpr.JPR_D_20_00117 [31] Fueki K,Inamochi Y,Wada J,et al. A systematic review of digital removable partial dentures. Part I: Clinical evidence,digital impression,and maxillomandibular relationship record[J]. J Prosthodont Res,2022,66(1):40-52. doi: 10.2186/jpr.JPR_D_20_00116 [32] Chang I C,Hung C C,Du J K,et al. Accuracy of intraoral scanning methods for maxillary Kennedy class I arch[J]. J Dent Sci,2023,18(2):747-753. doi: 10.1016/j.jds.2022.12.006 [33] Pjetursson B E,Valente N A,Strasding M,et al. A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic single crowns[J]. Clin Oral Implants Res,2018,29(16):199-214. [34] Michelinakis G,Apostolakis D,Kamposiora P,et al. The direct digital workflow in fixed implant prosthodontics: A narrative review[J]. BMC Oral Health,2021,21(1):37. doi: 10.1186/s12903-021-01398-2 [35] Sawase T,Kuroshima S. The current clinical relevancy of intraoral scanners in implant dentistry[J]. Dent Mater J,2020,39(1):57-61. doi: 10.4012/dmj.2019-285 [36] Pesce P,Pera F,Setti P,et al. Precision and accuracy of a digital impression scanner in full-arch implant rehabilitation[J]. Int J Prosthodont,2018,31(2):171-175. doi: 10.11607/ijp.5535 [37] 李瑾,高冬玲,李扬. CAD/CAM牙种植导板在上前牙列缺失即刻种植修复中的应用[J]. 陕西医学杂志,2020,49(11):1457-1460. doi: 10.3969/j.issn.1000-7377.2020.11.022 [38] 吴麒. 以修复为导向的CAD/CAM牙支持式种植导板指导临床种植(附病例报告)[J]. 中国口腔种植学杂志,2017,22(4):185-188. doi: 10.3969/j.issn.1007-3957.2017.04.010 [39] Zaniol T,Zaniol A,Ravazzolo S. The low window technique: Comparison between manual and CAD/CAM-guided design[J]. J Contemp Dent Pract,2021,22(4):400-405. doi: 10.5005/jp-journals-10024-3079 [40] Yeung S,Aghvinian R,Aalam A A,et al. CAD-CAM approach to designing and fabricating a low-maintenance metal-acrylic resin implant-supported fixed complete dental prosthesis: A clinical report[J]. J Prosthet Dent,2021,125(5):719-722. doi: 10.1016/j.prosdent.2020.04.006 [41] Baba N Z,Goodacre B J,Goodacre C J,et al. CAD/CAM complete denture systems and physical properties: A review of the literature[J]. J Prosthodont,2021,30(2):113-124. [42] Lehmann K M,Weyhrauch M,Bjelopavlovic M,et al. Marginal and internal precision of zirconia four-unit fixed partial denture frameworks produced using four milling systems[J]. Materials (Basel),2021,14(10):2663. doi: 10.3390/ma14102663 [43] Srimaneepong V,Heboyan A,Zafar M S,et al. Fixed prosthetic restorations and periodontal health: A narrative review[J]. J FunctBiomater,2022,13(1):15. [44] Janeva N M,Kovacevska G,Elencevski S,et al. Advantages of CAD/CAM versus conventional complete dentures - A review[J]. Open Access Maced J Med,2018,6(8):1498-1502 doi: 10.3889/oamjms.2018.308 [45] LeSage B P. CAD/CAM: Applications for transitional bonding to restore occlusal vertical dimension[J]. J Esthet Restor Dent,2020,32(2):132-140. doi: 10.1111/jerd.12554 [46] Krastev T,Payer M,Krastev Z,et al. The utilisation of CAD/CAM technology amongst Austrian dentists: A pilot study[J]. Int Dent J,2023,73(3):430-434. doi: 10.1016/j.identj.2022.09.004
点击查看大图
计量
- 文章访问数: 1838
- HTML全文浏览量: 646
- PDF下载量: 36
- 被引次数: 0