Volume 44 Issue 10
Oct.  2023
Turn off MathJax
Article Contents
Qian XIAO, Kun ZHOU, Lei WANG, Jun GAO, Junrun CHEN, Yalan REN. Accuracy of iTero Element 1 Intraoral Scanner Digital Model in Mild to Moderate Crowding of the Maxillary and Mandibular Arch[J]. Journal of Kunming Medical University, 2023, 44(10): 149-154. doi: 10.12259/j.issn.2095-610X.S20231025
Citation: Qian XIAO, Kun ZHOU, Lei WANG, Jun GAO, Junrun CHEN, Yalan REN. Accuracy of iTero Element 1 Intraoral Scanner Digital Model in Mild to Moderate Crowding of the Maxillary and Mandibular Arch[J]. Journal of Kunming Medical University, 2023, 44(10): 149-154. doi: 10.12259/j.issn.2095-610X.S20231025

Accuracy of iTero Element 1 Intraoral Scanner Digital Model in Mild to Moderate Crowding of the Maxillary and Mandibular Arch

doi: 10.12259/j.issn.2095-610X.S20231025
  • Received Date: 2023-07-27
    Available Online: 2023-09-12
  • Publish Date: 2023-10-25
  •   Objective  To evaluate the accuracy of digital models obtained using the iTero Element 1 intraoral scanner and traditional plaster models for measurements in mild to moderate crowding.   Methods   37 patients who sought treatment at the Qinxing Road Clinic of Kunming Medical University Affiliated Stomatological Hospital were selected. The iTero Element 1 intraoral scanner was used to obtain digital models, while alginate impression was used to obtain traditional plaster models. The differences in digtal measurements and manual measurements of the traditional plaster models of tooth crown width, dental arch width, and coverage were compared.   Results  The ICC value of the three repeated measurements for both digital and plaster models were all above 0.9, indicating good repeatability. There were statistically significant differences in the arch width of 14~24 in mild and moderate crowded group, crown width (11、16、21、31、36、41、43、46) and 22 overjet in mild crowded group, and crown width of (11、23、16、31)and 11、12 overjet in moderate crowded group.   Conclusion   There are some differences between the data from iTero digital models and the manually measured plaster models in cases of mild to moderate crowding. This may be due to misalignment of teeth, leading to measurement errors. However, the differences in measurement data are small and do not affect the clinical application of iTero digital models.
  • loading
  • [1]
    赵志河主编. 口腔正畸学[M]. 第7版. 北京: 北京人民卫生出版社, 2020: 54-172.
    [2]
    Su T S,Shu J. Intraoral digital impression technique: A review[J]. J Prosthodont,2015,24(4):313-321. doi: 10.1111/jopr.12218
    [3]
    葛峻沂,王佩佩,周鹏,等. iTero口腔数字化扫描软件在口腔正畸教学中的应用探索[J]. 科教导刊,2023,(12):88-90.
    [4]
    程明轩,姜婷,孙玉春,等. 比较口内扫描和模型扫描对数字化牙列模型咬合定量分析的影响[J]. 北京大学学报(医学版),2018,50(1):136-140.
    [5]
    游恺,张宁. 五种口内扫描仪模型扫描精度对比及扫描质量评估[J]. 口腔颌面修复学杂志,2023,24(4):259-265.
    [6]
    郑小婉,刘金平,黄晓峰. 轻重度拥挤正畸模型手工测量和数字化测量的可靠性评价研究[J]. 临床口腔医学杂志,2021,37(7):395-399.
    [7]
    游恺,张宁. 三种口内扫描仪精度的对比研究[J]. 口腔颌面修复学杂志,2023,24(2):87-92.
    [8]
    张晖榕,尹乐锋,刘艳丽,等. 基于锥形术CT数字化建模的3D打印牙颌模型制作及精确度研究[J]. 华西口腔医学杂志,2018,36(2):156-161.
    [9]
    Kravitz N D,Groth C,Jones P E,et al. Intraoral digital scanners[J]. J Clin Orthod,2014,48(6):337-347.
    [10]
    Flugge T V,Schlager S,Nelson K,et al. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner[J]. Am J Orthod Dentofacial Orthop,2013,144(3):471-478. doi: 10.1016/j.ajodo.2013.04.017
    [11]
    Zhang F,Suh K J,Lee K M. Validity of intraoral scans compared with plaster models: An in-vivo comparison of dental measurements and 3D surface analysis[J]. PLoS One,2016,11(6):e157713.
    [12]
    Leifert M F,Leifert M M,Efstratiadis S S,et al. Comparison of space analysis evaluations with digital models and plaster dental casts[J]. Am J Orthod Dentofacial Orthop,2009,136(1):16.e1-16. doi: 10.1016/j.ajodo.2009.05.002
    [13]
    杨雷宁,韩晓鹏,张萌萌,等. 牙颌数字化模型与石膏模型在线距和角度测量方面的准确性研究[J]. 口腔医学研究,2019,35(8):802-805.
    [14]
    刘静. 口内扫描仪全牙列扫描精度及不同操作者间扫描精度差异的研究[D]. 济南: 山东大学, 2017.
    [15]
    Su T S,Sun J. Comparison of repeatability between intraoral digital scanner and extraoral digital scanner:An in-vitro study[J]. Journal of Prosthodontic Research,2015,59(4):236-242.
    [16]
    Liang Y M,Rutchakitprakarn L,Kuang S H,et al. Comparing the reliability and accuracy of clinical measurements using plaster model and the digital model system based on crowding severity[J]. J Chin Med Assoc,2018,81(9):842-847. doi: 10.1016/j.jcma.2017.11.011
    [17]
    谢轶伦,沈刚. 全口牙列口内扫描的精确性与可重复性分析[J]. 上海口腔医学,2016,25(5):593-599.
    [18]
    Kim J,Heo G,Lagravere M O. Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography[J]. Angle Orthod,2014,84(3):443-450. doi: 10.2319/051213-365.1
    [19]
    Luu N S,Nikolcheva L G,Retrouvey J M,et al. Linear measurements using virtual study models[J]. Angle Orthod,2012,82(6):1098-1106. doi: 10.2319/110311-681.1
    [20]
    Asquith J,Gillgrass T,Mossey P. Three-dimensional imaging of orthodontic models: A pilot study[J]. Eur J Orthod,2007,29(5):517-522. doi: 10.1093/ejo/cjm044
    [21]
    Santoro M,Galkin S,Teredesai M,et al. Comparison of measurements made on digital and plaster models[J]. Am J Orthod Dentofacial Orthop,2003,124(1):101-105. doi: 10.1016/S0889-5406(03)00152-5
    [22]
    McCann J,Burden D J. An investigation of tooth size in Northern Irish people with bimaxillary dental protrusion[J]. Eur J Orthod,1996,18(6):617-621. doi: 10.1093/ejo/18.6.617
    [23]
    Yuzbasioglu E,Kurt H,Turunc R,et al. Comparison of digital and conventional impression techniques: evaluation of patients’ perception,treatment comfort,effectiveness and clinical outcomes[J]. BMC Oral Health,2014,14:10. doi: 10.1186/1472-6831-14-10
  • Relative Articles

    [1] Yanjie LI, Mingzhu CHEN, Jiangtian HU. Application Prospect of Digital Integration Technology in Multidisciplinary Collaborative Orthodontic Treatment. Journal of Kunming Medical University, 2024, 45(8): 1-6.  doi: 10.12259/j.issn.2095-610X.S20240801
    [2] Jing ZHOU, Liqiong CHEN, Wenjuan FENG, Changyun WU, Su SUN, Changquan LI, Quan WANG. Application of Oral Digital Positioning System Combined with CBL in The Teaching of Orthodontic Bracket Bonding and Positioning. Journal of Kunming Medical University, 2023, 44(1): 151-155.  doi: 10.12259/j.issn.2095-610X.S20230127
    [3] Juanjuan JI, Yali LIU, Zhi ZHOU, Yanhua XU, Yaling ZHU, Rui WANG. The Intervention of Digital Technology in the Correction of Maxillary Labial High Canine Teeth. Journal of Kunming Medical University, 2023, 44(9): 75-79.  doi: 10.12259/j.issn.2095-610X.S20230923
    [4] Xia LI, Jin WANG. Comparions of the Diagnostic Value between Digital Breast Tomosynthesis and Full-field Digital Mammography. Journal of Kunming Medical University, 2022, 43(9): 118-124.  doi: 10.12259/j.issn.2095-610X.S20220914
    [5] Qin XIE, Yan-ping LIANG, Yin ZHANG, Zeng-hui XU, Li-ying YOU. Efficacy of Multiple Non-invasive Diagnostic Models in the Diagnosis of Hepatic Fibrosis in Patients with Chronic Liver Diseases. Journal of Kunming Medical University, 2021, 42(7): 115-120.  doi: 10.12259/j.issn.2095-610X.S20210719
    [6] Zi-yan YANG, Xing-xing LI, Yun-hong LIN. Clinical Effect of Digital Complete Dentures for Edentulous Patients. Journal of Kunming Medical University, 2021, 42(3): 84-88.  doi: 10.12259/j.issn.2095-610X.S20210322
    [7] Dong Yuan , Li Cai Xia , Zhao Xian , Tuo Xiao Yu , Liu Liu , Ma Yun . . Journal of Kunming Medical University, 2020, 41(05): 29-32.
    [8] Tan Ya Xin , Li Shan , Wang Ting Hua , Xi Yang Yan Bin . . Journal of Kunming Medical University, 2019, 40(12): 7-12.
    [9] Li Jun Man , Qian Jie , Yin Yi , Peng Yi , Shui Yan Qing , Yang Chun , Hu Yu , Yang He Feng . . Journal of Kunming Medical University, 2019, 40(11): 156-160.
    [10] Hou Yun He , Zhang Hao Xin , Wang Yi Yu , Su Yan Mei , Gu Dan Shan , Lin Shao Fang , Yang Shi Kun , Li Shu De . Regulatory Mechanism of Ginsenoside Rg1 on Homocysteine in NAFLD Model. Journal of Kunming Medical University, 2018, 39(04): 27-33.
    [11] Qian Cheng , Si Jing Lang , Tang Bo , Xiao Shu Feng , Fu Bi Mang , Zhang Jie . . Journal of Kunming Medical University, 2018, 39(09): 6-10.
    [12] Dong Zhao Xing . . Journal of Kunming Medical University,
    [13] Liu Yan . . Journal of Kunming Medical University,
    [14] Li Yuan . . Journal of Kunming Medical University,
    [15] Chen Yuan . . Journal of Kunming Medical University,
    [16] Chen Jiao Li . Progress in Diabetic Rat Model. Journal of Kunming Medical University,
    [17] Yan Yong Ji . Establishment of a Rat Model of Aldosterone-Producing Adenoma. Journal of Kunming Medical University,
    [18] He Bin . . Journal of Kunming Medical University,
    [19] . Establishment of Human Immune Reconstitute NOD/SCID Mice Model. Journal of Kunming Medical University,
    [20] Wang Ai Ping . . Journal of Kunming Medical University,
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Tables(6)

    Article Metrics

    Article views (1852) PDF downloads(27) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return