  • In recent years, computer-aided design and manufacturing (CAD/CAM) have been driving the development and reform of the dental field. Prosthodontics is an essential part of oral medicine, and CAD/CAM is increasingly being used in prosthodontics, leading to rapid advancements in this field. This paper summarizes a number of domestic and international literatures to provide an overview of the progress of CAD/CAM in prosthodontics.
  • loading
  • [1]
    Miyazaki T,Hotta Y,Kunii J,et al. A review of dental CAD/CAM: Current status and future perspectives from 20 years of experience[J]. Dent Mater J,2009,28(1):44-56. doi: 10.4012/dmj.28.44
    [2]
    黄清川,黄翠,蔡新杰. 数字化口内扫描技术在口腔修复学临床和教学中的应用[J]. 口腔颌面修复学杂志,2022,23(5):366-373.
    [3]
    Chi J. Digital impressions and in-office CAD/CAM: A review of best practices and what's to come[J]. Compend Contin Educ Dent,2021,42(3):140-141.
    [4]
    Fung L,Brisebois P. Implementing digital dentistry into your esthetic dental practice[J]. Dent Clin North Am,2020,64(4):645-657. doi: 10.1016/j.cden.2020.07.003
    [5]
    Tanveer W,Ridwan-Pramana A,Molinero-Mourelle P,et al. Systematic review of clinical applications of CAD/CAM technology for craniofacial implants placement and manufacturing of orbital prostheses[J]. Int J Environ Res Public Health,2021,18(21):11349. doi: 10.3390/ijerph182111349
    [6]
    Mühlemann S,Benic G I,Fehmer V,et al. Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic posterior fixed partial dentures. Part II: Time efficiency of CAD-CAM versus conventional laboratory procedures[J]. J Prosthet Dent,2019,121(2):252-257. doi: 10.1016/j.prosdent.2018.04.020
    [7]
    Khan S,Ali A,Siddique R,et al. Novel coronavirus is putting the whole world on alert[J]. J Hosp Infect,2020,104(3):252-253. doi: 10.1016/j.jhin.2020.01.019
    [8]
    Barenghi L,Barenghi A,Garagiola U,et al. Pros and Cons of CAD/CAM technology for infection prevention in dental settings during COVID-19 outbreak[J]. Sensors (Basel),2021,22(1):49. doi: 10.3390/s22010049
    [9]
    Komine F,Honda J,Kusaba K,et al. Clinical outcomes of single crown restorations fabricated with resin-based CAD/CAM materials[J]. J Oral,2020,62(4):353-355. doi: 10.2334/josnusd.20-0195
    [10]
    Krug R,Droste L,Schreiber C,et al. Long-term performance of ceramic in/-onlays vs. cast gold partial crowns - a retrospective clinical study[J]. Clin Oral Investig,2024,28(5):298. doi: 10.1007/s00784-024-05682-7
    [11]
    Metiner C,Türker Ş B. Evaluation of clinical success and marginal adaptations of inlay and onlay restorations manufactured after conventional and digital impressions: A prospective randomized controlled clinical study[J]. Int J Comput Dent,2021,24(2):207-223.
    [12]
    Bustamante-Hernández N,Montiel-Company J M,Bellot-Arc í s C,et al. Clinical behavior of ceramic,hybrid and composite onlays. A systematic review and meta-analysis[J]. IntJ Environ Res Public Health,2020,17(20):7582. doi: 10.3390/ijerph17207582
    [13]
    Vagropoulou G I,Klifopoulou G L,Vlahou S G,et al. Complications and survival rates of inlays and onlays vs complete coverage restorations: A systematic review and analysis of studies[J]. J Oral Rehabil,2018,45(11):903-920. doi: 10.1111/joor.12695
    [14]
    Tunac A T,Celik E U,Yasa B. Two-year performance of CAD/CAM fabricated resin composite inlay restorations: A randomized controlled clinical trial[J]. J Esthet Restor Dent,2019,31(6):627-638. doi: 10.1111/jerd.12534
    [15]
    Mandal N B,Kumari A,Baldev K C,et al. A clinical evaluation of onlay and inlay in the posterior ceramic restorations: An original study[J]. J Pharm Bioallied,2022,14(1):310-312.
    [16]
    张锋娟,宋长钦. CAD/CAM高嵌体修复根管治疗后磨牙大面积缺损的临床应用[J]. 北京口腔医学,2021,29(6):370-373.
    [17]
    刘方宇,朱加林,丁存善,等. CAD/CAM氧化锆髓超嵌体修复磨牙根管治疗后牙体缺损的临床效果评价[J]. 宁夏医科大学报,2021,43(1):52-56.
    [18]
    Arcuri L,Lorenzi C,Bianchi N,et al. Fit evaluation of cad/cam fabricated all-ceramic restorations based on direct and indirect digitalization in vivo: A systematic review[J]. J Biol Regul Homeost Agents,2019,33(3):103-111.
    [19]
    Khamverdi Z,Najafrad E,Farhadian M. In vitro comparison of marginal and internal fit of zirconia copings fabricated by one CAD/CAM system with two different scanners[J]. Front Dent,2021,20(1):18-21.
    [20]
    Scaringi R,Nannelli M,Franchina A,et al. Full zirconia implant-born prosthetic rehabilitation with CAD/CAM technology after accurate digital planning A Case Report[J]. Int J Environ Res Public Health,2021,18(15):7998. doi: 10.3390/ijerph18157998
    [21]
    Rodrigues S B,Franken P,Celeste R K,et al. CAD/CAM or conventional ceramic materials restorations longevity: A systematic review and meta-analysis[J]. J Prosthodont Res,2019,63(4):389-395. doi: 10.1016/j.jpor.2018.11.006
    [22]
    Aswal G S,Rawat R,Dwivedi D,et al. Clinical outcomes of CAD/CAM (Lithium disilicate and Zirconia) based and conventional full crowns and fixed partial dentures: A systematic review and meta-analysis[J]. Cureus,2023,15(4):e37888.
    [23]
    Hallmann L,Ulmer P,Wille S,et al. Effect of differences in coefficient of thermal expansion of veneer and Y-TZP ceramics on interface phase transformation[J]. J Prosthet Dent,2014,112(3):591-599. doi: 10.1016/j.prosdent.2013.11.009
    [24]
    Kim J J. Revisiting the removable partial denture[J]. Dent Clin North Am,2019,63(2):263-278. doi: 10.1016/j.cden.2018.11.007
    [25]
    Arnold C,Hey J,Schweyen R,et al. Accuracy of CAD-CAM-fabricated removable partial dentures[J]. J Prosthet Dent,2018,119(4):586-592. doi: 10.1016/j.prosdent.2017.04.017
    [26]
    Maeda Y,Minoura M,Tsutsumi S,et al. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures[J]. Int J Prosthodont,1994,7(1):17-21.
    [27]
    Anadioti E,Musharbash L,Blatz MB,et al. 3D printed complete removable dental prostheses: A narrative review[J]. BMC Oral Health,2020,27;20(1):343.
    [28]
    Ahmed N,Abbasi M S,Haider S,et al. Fit accuracy of removable partial denture frameworks fabricated with CAD/CAM,rapid prototyping,and conventional techniques: A systematic review[J]. Biomed Res Int,2021,6(9):319433.
    [29]
    Arafa K A O. Assessment of the fit of removable partial denture fabricated by computer-aided designing/computer aided manufacturing technology[J]. Saudi Med J,2018,39(1):17-22. doi: 10.15537/smj.2018.1.20796
    [30]
    Takaichi A,Fueki K,Murakami N,et al. A systematic review of digital removable partial dentures. Part II: CAD/CAM framework,artificial teeth,and denture base[J]. J Prosthodont Res,2022,66(1):53-67. doi: 10.2186/jpr.JPR_D_20_00117
    [31]
    Fueki K,Inamochi Y,Wada J,et al. A systematic review of digital removable partial dentures. Part I: Clinical evidence,digital impression,and maxillomandibular relationship record[J]. J Prosthodont Res,2022,66(1):40-52. doi: 10.2186/jpr.JPR_D_20_00116
    [32]
    Chang I C,Hung C C,Du J K,et al. Accuracy of intraoral scanning methods for maxillary Kennedy class I arch[J]. J Dent Sci,2023,18(2):747-753. doi: 10.1016/j.jds.2022.12.006
    [33]
    Pjetursson B E,Valente N A,Strasding M,et al. A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic single crowns[J]. Clin Oral Implants Res,2018,29(16):199-214.
    [34]
    Michelinakis G,Apostolakis D,Kamposiora P,et al. The direct digital workflow in fixed implant prosthodontics: A narrative review[J]. BMC Oral Health,2021,21(1):37. doi: 10.1186/s12903-021-01398-2
    [35]
    Sawase T,Kuroshima S. The current clinical relevancy of intraoral scanners in implant dentistry[J]. Dent Mater J,2020,39(1):57-61. doi: 10.4012/dmj.2019-285
    [36]
    Pesce P,Pera F,Setti P,et al. Precision and accuracy of a digital impression scanner in full-arch implant rehabilitation[J]. Int J Prosthodont,2018,31(2):171-175. doi: 10.11607/ijp.5535
    [37]
    李瑾,高冬玲,李扬. CAD/CAM牙种植导板在上前牙列缺失即刻种植修复中的应用[J]. 陕西医学杂志,2020,49(11):1457-1460. doi: 10.3969/j.issn.1000-7377.2020.11.022
    [38]
    吴麒. 以修复为导向的CAD/CAM牙支持式种植导板指导临床种植(附病例报告)[J]. 中国口腔种植学杂志,2017,22(4):185-188. doi: 10.3969/j.issn.1007-3957.2017.04.010
    [39]
    Zaniol T,Zaniol A,Ravazzolo S. The low window technique: Comparison between manual and CAD/CAM-guided design[J]. J Contemp Dent Pract,2021,22(4):400-405. doi: 10.5005/jp-journals-10024-3079
    [40]
    Yeung S,Aghvinian R,Aalam A A,et al. CAD-CAM approach to designing and fabricating a low-maintenance metal-acrylic resin implant-supported fixed complete dental prosthesis: A clinical report[J]. J Prosthet Dent,2021,125(5):719-722. doi: 10.1016/j.prosdent.2020.04.006
    [41]
    Baba N Z,Goodacre B J,Goodacre C J,et al. CAD/CAM complete denture systems and physical properties: A review of the literature[J]. J Prosthodont,2021,30(2):113-124.
    [42]
    Lehmann K M,Weyhrauch M,Bjelopavlovic M,et al. Marginal and internal precision of zirconia four-unit fixed partial denture frameworks produced using four milling systems[J]. Materials (Basel),2021,14(10):2663. doi: 10.3390/ma14102663
    [43]
    Srimaneepong V,Heboyan A,Zafar M S,et al. Fixed prosthetic restorations and periodontal health: A narrative review[J]. J FunctBiomater,2022,13(1):15.
    [44]
    Janeva N M,Kovacevska G,Elencevski S,et al. Advantages of CAD/CAM versus conventional complete dentures - A review[J]. Open Access Maced J Med,2018,6(8):1498-1502 doi: 10.3889/oamjms.2018.308
    [45]
    LeSage B P. CAD/CAM: Applications for transitional bonding to restore occlusal vertical dimension[J]. J Esthet Restor Dent,2020,32(2):132-140. doi: 10.1111/jerd.12554
    [46]
    Krastev T,Payer M,Krastev Z,et al. The utilisation of CAD/CAM technology amongst Austrian dentists: A pilot study[J]. Int Dent J,2023,73(3):430-434. doi: 10.1016/j.identj.2022.09.004
  • Relative Articles

    [1] Weimin QIAN, Liangju CAO, Yu JIANG, Dan PU, Fengting MU, Yongsheng PAN. Effect of Photo-activated Disinfection as An Adjunctive Therapy in the Treatment of Chronic Periodontitis. Journal of Kunming Medical University, 2024, 45(1): 136-142.  doi: 10.12259/j.issn.2095-610X.S20240123
    [2] Leijing RAN, Shaohua WANG, Lintong LI, Li GUI. A Meta-analysis of the Effect of Adjuvant Probiotics in Patients with Osteoporosis. Journal of Kunming Medical University, 2024, 45(2): 65-76.  doi: 10.12259/j.issn.2095-610X.S20240209
    [3] Hao HUANG, Xuelin LI, Fei SONG, Xiuling JI, Yingying XIANG. Applications of Biologically Oriented Preparation Technique in Prosthodontics. Journal of Kunming Medical University, 2024, 45(1): 168-171.  doi: 10.12259/j.issn.2095-610X.S20240128
    [4] Yunrong XU, Ziwen TANG, Fei HE. Molecular Mechanisms of Osteogenesis Promoted by Bone Repair Materials. Journal of Kunming Medical University, 2023, 44(10): 168-179.  doi: 10.12259/j.issn.2095-610X.S20231007
    [5] Yang Jin Yu , Liu Ying Ying , Wang Wei Hong , Yao Lan . . Journal of Kunming Medical University, 2020, 41(08): 171-175.
    [6] Xiang Ying Ying , Pi Ting , Song Fei , Yang Xiang Hong , Wei Yun Lin , Ji Xiu Ling . . Journal of Kunming Medical University, 2020, 41(08): 162-166.
    [7] Wang Xiao Li , Yu Ting , Wang Hu . . Journal of Kunming Medical University, 2019, 40(01): 109-111.
    [8] Luo Xi , Wu Ze , Li Yong Gang , Dong Yun Hua , Gao Meng Ying , Deng Lian , Xiang Li Feng , Li Ming Ying . . Journal of Kunming Medical University, 2018, 39(10): 72-78.
    [9] Zhang Li , Zhao Dong Yan , Liu Hua . An Application of Haiao Prosthodontics Membrane in the Repair of Palatal Fistula. Journal of Kunming Medical University, 2018, 39(02): 112-116.
    [10] He Li Ming , He Yong Wen . . Journal of Kunming Medical University, 2017, 38(03): 31-34.
    [11] Zhu Tian Bo . Clinical Application of Preoperative New Adjuvant Chemotherapy in Treatment of Cervical Cancer. Journal of Kunming Medical University,
    [12] Yang Jing . . Journal of Kunming Medical University,
    [13] Yang Zong Jia . . Journal of Kunming Medical University,
    [14] Huang Shao Li . . Journal of Kunming Medical University,
    [15] Zhang Yi Fan . . Journal of Kunming Medical University,
    [16] Wu Zhi Yong . . Journal of Kunming Medical University,
    [17] . The Diagnostic Value of Vibration Response Imaging System Assisting Bedside Chest Radiography in Differentiating Thoracics. Journal of Kunming Medical University,
    [18] . The Preparation of Silk-fibroin Nano-fibers with Air-assisted Electrospinning. Journal of Kunming Medical University,
    [19] Tao Yong . . Journal of Kunming Medical University,
    [20] Song Li . . Journal of Kunming Medical University,
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (1837) PDF downloads(36) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return