Chen Hai Tao , Yang Li Chun , Hai Sai Ping , Luo Xiao Mao . Value of Contrast Enhanced Ultrasonography in Catheter Drainage[J]. Journal of Kunming Medical University, 2018, 39(04): 62-65.
Citation: Chen Hai Tao , Yang Li Chun , Hai Sai Ping , Luo Xiao Mao . Value of Contrast Enhanced Ultrasonography in Catheter Drainage[J]. Journal of Kunming Medical University, 2018, 39(04): 62-65.

Value of Contrast Enhanced Ultrasonography in Catheter Drainage

Funds:

基金: 国家自然科学基金资助项目 (81560497);

  • Received Date: 2017-11-08
  • Objective To investigate the value of contrast enhanced ultrasonography in catheter drainage to determine the position and patency of catheter. Me thods We made a retrospective analysis in patients (78 cases) received percutaneous ultrasound-guided catheter drainage and diluted ultrasound contrast agents injection, and observed the catheter position and drainage effect. Re s ults Eighty-one drainage catheters developed the whole tube clearly, with catheter tips located at a predetermined position and the contrast agent diffusion region coincided with the predetermined region, accounting for 87.1%. Five catheter tips were unclear, while the contrast agent diffusion region coincided with the predetermined region, accounting for 5.4%. Three catheter tips failed to reach the predetermined position, and four drainage catheters developed part of the body of tubes clearly and showed cut off, accounting for 7.5%. Seven drainage catheter were pulled out and placed again, and then injected the diluted ultrasound contrast agent. In the replaced catheters, the catheters developed the whole tube clearly, catheter tips located at a predetermined position, and the contrast agent diffusion region coincided with the predetermined region.Conclus ion Contrast enhanced ultrasonography by diluted ultrasound contrast agent Sonovue injection through catheter can display drainage catheter, and determine the location of the catheter and drainage area. It is a reliable and non-invasive method and has a high clinical value.
  • [1]赵宇, 王墨飞, 张远石, 等.超声引导经皮肝穿刺置管引流治疗细菌性肝脓肿36例分析[J].中国实用外科杂志, 2011, 31 (2) :167-185.
    [2]马建伟, 杨晓军, 付兆亮.经皮经肝胆囊穿刺置管引流术在高龄急性化脓性胆囊炎治疗中的价值[J].中国普外基础与临床杂志, 2016, 23 (2) :237-239.
    [3]苗凯玲, 侯惠如.胸腔置管引流治疗恶性胸腔积液的研究进展[J].解放军医学院学报, 2018 39 (1) :57-59.
    [4]罗飞, 王琰, 和朝平, 等.超声造影在经皮经肝穿刺胆汁引流中的应用[J].临床误诊误治, 2008, 21 (12) :51-52.
    [5]许尔蛟, 郑荣琴, 李凯, 等.胆管内超声造影在经皮经肝弹道引流术中的应用价值[J].中华医学超声杂志, 2011, 8 (9) :1937-1944.
    [6]吕新华.胆道超声造影在经皮经肝胆道穿刺引流术后引流不畅患者中的应用价值[J].中国超声医学杂志, 2015, 31 (9) :801-803.
    [7]姜兆鹏, 周显礼, 纪巧.超声引导下经皮经肝穿刺胆囊置管引流术治疗性胆源性胰腺炎[J].中国介入影像与治疗学, 2015, 12 (10) :588-591.
    [8]
    [8]ROTMAN J A, GETRAJDMAN G I, MAYBODY M.Effect of abdominopelvic abscess drain size on drainage time and probability of occlusion[J].Am J Surg, 2017, 213 (4) :718-722.
    [9]梁雪勤.综合护理干预在预防术后引流管脱落中的应用[J].医学理论与实践, 2016, 29 (24) :3407-3408.
    [10]郑言利, 宁彩芳, 聂明斐.腹腔引流管的护理体会[J].中国实用医药, 2015, 10 (2) :194-195.
    [11]张艳梅, 李娟.胸腔闭式引流的护理效果观察[J].临床医学研究与实践, 2016, 1 (20) :171-174.
    [12]蔡丽萍, 王琳, 赵克立, 等.胆管超声造影在肝内胆管置管引流术式选择中的应用价值[J].中华医学超声杂志, 2011, 5 (8) :2476-2477.
    [13]苗莉莉, 孙尧, 王刚, 等.超声造影在经皮经肝胆道引流术中的临床应用[J].医学影像学杂志, 2012, 22 (11) :1894-1897.
    [14]吕孟斐, 国义民, 王建国.45%泛影葡胺经引流管造影在胆囊切除术后胆漏患者治疗中的应用研究[J].河北医药, 2015, 37 (15) :2320-2322.
    [15]刘小玲.泛影葡胺临床新用的价值[J].中国实用医药, 2014, 9 (12) :76.
    [16]
    [16]THORNTON R H, COVEY A M.Urinary drainage procedures in interventional radiology[J].Tech Vasc Interv Radiol.2016, 19 (3) :170-181.
    [17]孔艳鹏, 冯雷, 夏要友, 等.对比增强超声在非血管性腔道中的应用[J].中国医学影像学杂志, 2014, 22 (9) :704-707.
    [18]赵东, 胡晓林, 段闽江.造影剂过敏反应的预防和处理[J].临床误诊误治, 2015, 18 (11) :840.
    [19]梁瑶, 孙路路.碘造影剂过敏样反应发生机制研究进展及防治[J].临床药物治疗杂志, 2016, 14 (3) :6-10.
    [20]
    [20]JASPERS N, PFISTER R, KINKEL H, et al.Contrast-enhanced ultrasound[J].Dtsch Med Wochenschr, 2012, 137 (45) :2336-2339.
    [21]
    [21]FURLOW B.Contrast-enhanced ultrasound[J].Radiol Technol, 2009, 80 (6) 547-561.
  • Relative Articles

    [1] Wenxiu XU, Xiaofeng MO, Xiangmin YANG, Silu YANG, Fan WU, Te LI. Application of Logistic Regression and Decision Tree Model in Prediction of Adverse Reactions of Iodinated Contrast Medium. Journal of Kunming Medical University, 2024, 45(9): 70-75.  doi: 10.12259/j.issn.2095-610X.S20240911
    [2] Yuping DUAN, Hualei ZHAO, Xueliang FEI, Yongxin TANG, Yongsheng XU. Early Efficacies of Drainage in Arthroscopic Reconstruction with Anterior Cruciate Ligament Reconstruction. Journal of Kunming Medical University, 2024, 45(1): 122-126.  doi: 10.12259/j.issn.2095-610X.S20240120
    [3] , . . Journal of Kunming Medical University, 2024, 45(1B): 7-8.
    [4] Yan SHEN, Yongfeng LI, Chunhua XIAO, Hong LI, Wei YANG, Shengning ZHANG, Yanqiong LV, Wandong YANG, Shilan. DING. Application of Multimodal Ultrasound in Post-operative Monitoring of Transplanted Livers by Donors after the Brain Death. Journal of Kunming Medical University, 2022, 43(9): 90-95.  doi: 10.12259/j.issn.2095-610X.S20220917
    [5] Jianfei LU, Rui BU, Xiaoyan LIU, Xing ZHANG, Yu DING, Ran ZHANG. Efficacy of Conventional Ultrasound and Contrast-enhanced Ultrasound in Preoperative Diagnosis of Lateral Cervical Lymph Node Metastasis from Papillary Thyroid Carcinoma. Journal of Kunming Medical University, 2022, 43(12): 75-80.  doi: 10.12259/j.issn.2095-610X.S20221214
    [6] Li Ying Hua , Gao Jing , Yuan Yuan , Wu Shi Cong , Ding Yun Chuan . . Journal of Kunming Medical University, 2020, 41(06): 95-99.
    [7] Ju-xiang MA, Yong-hong MA, Shan-shan GAO, Jue WU, Min ZHU, Zhen-ling DUAN. Value of Intravenous Contrast-enhanced Ultrasound in Differential Diagnosis of Adenomyosis and Uterine Fibroids. Journal of Kunming Medical University, 2020, 41(11): 114-118.  doi: 10.12259/j.issn.2095-610X.S20201109
    [8] Zou Hua Li . . Journal of Kunming Medical University, 2019, 40(08): 63-66.
    [9] Miao Wen Qing , Wang Yu , Yang Jun , Zhang Yi Hong , Tian Qing , Duan Hui Xian , Zhao Zhong Wen , Wang Yan , Yang Xing Hu . Correlation study of the Predictive Value of Beta-trace Protein to Contrast-induced Nephropathy after Coronary Intervention. Journal of Kunming Medical University, 2018, 39(07): 114-118.
    [10] Nian Ying Hua , Shen Ruo Xia , Chuan Zhi Rui , Qu Yin Xi , Yang Li Chun . . Journal of Kunming Medical University, 2017, 38(05): 87-90.
    [11] Luo Xiao Mao . Application of Double Contrast-enhanced Ultrasonography in the Diagnosis of Gastric Cancer. Journal of Kunming Medical University,
    [12] Wu Jue . Diagnostic Value of Contrast-enhanced Ultrasonography in Differentiating Benign and Malignant Tumor of Pelvic Cavity. Journal of Kunming Medical University,
    [13] Yao Ming Ying . . Journal of Kunming Medical University,
    [14] Dai Rui . . Journal of Kunming Medical University,
    [15] Lu Jian Fei . . Journal of Kunming Medical University,
    [16] Chen Shi Gui . . Journal of Kunming Medical University,
    [17] Xia Yao You . . Journal of Kunming Medical University,
    [18] Chen Hai Tao . . Journal of Kunming Medical University,
    [19] . Value of Contrast-enhanced Ultrasound in Diagnosis of Prostate Cancer. Journal of Kunming Medical University,
    [20] Zhuang Yong Hui . . Journal of Kunming Medical University,
  • Cited by

    Periodical cited type(1)

    1. 李娴. 全程分期式健康教育在神经内科经外周静脉置入中心静脉导管术治疗患者中的干预效果分析. 四川解剖学杂志. 2020(04): 154-155 .

    Other cited types(0)

  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (2996) PDF downloads(71) Cited by(1)
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return