Volume 42 Issue 1
Jan.  2021
Turn off MathJax
Article Contents
Lin-kun TA, Yan-ling HUANG, Yong-ping LU. The Value of Echocardiography in Diagnosing Fetal Tetralogy of Fallot[J]. Journal of Kunming Medical University, 2021, 42(1): 142-146. doi: 10.12259/j.issn.2095-610X.S20210126
Citation: Lin-kun TA, Yan-ling HUANG, Yong-ping LU. The Value of Echocardiography in Diagnosing Fetal Tetralogy of Fallot[J]. Journal of Kunming Medical University, 2021, 42(1): 142-146. doi: 10.12259/j.issn.2095-610X.S20210126

The Value of Echocardiography in Diagnosing Fetal Tetralogy of Fallot

doi: 10.12259/j.issn.2095-610X.S20210126
  • Received Date: 2020-07-29
  • Publish Date: 2021-01-25
  •   Objective   To analyze the value of echocardiography in the diagnosis of fetal tetralogy of Fallot(TOF).   Methods   558 pregnant women who underwent fetal echocardiography in the department of ultrasound of the Second People's Hospital of Yunnan Province from January 2017 to June 2019 were selected as the research objects. The pathological anatomy after the induction of labor and the results of postpartum echocardiography follow-up were as used the gold standard to calculate the prenatal echocardiography. The diagnosis sensitivity, specificity, accuracy rate were shown, and the sound image characteristics of TOF were analyzed.   Results   A total of 558 pregnant women underwent the echocardiographic examination. After the induction of labor, pathological anatomy and postpartum echocardiographic follow-up results confirmed a total of 25 cases of TOF fetus. Prenatal echocardiography detected 26 cases of TOF fetus, 20 cases of typical TOF with pulmonary artery stenosis, 3 cases of pulmonary atresia with ventricular septal defect, 2 cases of TOF with absent pulmonary valve, 2 cases of misdiagnosis, and 1 case of missed diagnosis. The diagnostic sensitivity, specificity, accuracy, misdiagnosis rate and missed diagnosis rate of prenatal echocardiography were approximately 96%(24/25), 99.62%(531/533), 99.46%(555/558), 0.38%(2/533)and 4%(1/25), respectively. It is mainly characterized by ventricular septal defect, aortic straddling, pulmonary artery stenosis, atresia, and absence of pulmonary valve.   Conclusion   Prenatal fetal echocardiography is the most important imaging method for the diagnosis of TOF, and it has important clinical guiding significance for evaluating the prognosis of the fetus.
  • loading
  • [1]
    徐宏耀,姬建胜,王平凡,等. 704 例法洛四联症矫治术的临床分析[J].中国胸心血管外科临床杂志,2016,23(4):408-410.
    [2]
    张本,许炜,张卫达,等. 142例婴儿法洛四联症的外科治疗:附5年随访资料[J].第二军医大学学报,2017,38(1):119-123.
    [3]
    李胜利. 胎儿畸形产前超声与病理解剖图谱. 胸腔、心脏和腹部分卷[M]. 北京: 人民军医出版社, 2015: 322-328.
    [4]
    付晨. 产前超声心动图在胎儿法洛四联症诊断中的应用价值[J].医疗装备,2019,32(20):131-132. doi: 10.3969/j.issn.1002-2376.2019.20.088
    [5]
    张红,赵跃华,王艳艳,等. 不同超声切面和STIC 技术诊断胎儿法洛四联症的价值分析[J].徐州医学院学报,2017,37(6):384-385.
    [6]
    王海旺. 超声心动图在诊断胎儿法洛四联症中的价值[J].数理医药学杂志,2018,31(6):849-850. doi: 10.3969/j.issn.1004-4337.2018.06.028
    [7]
    付煜玮,翁宗杰,孙宝娟,等. 胎儿超声心动图结合大血管铸型对胎儿心脏畸形的漏误诊分析[J].中国超声医学杂志,2017,33(4):322-325. doi: 10.3969/j.issn.1002-0101.2017.04.013
    [8]
    徐霞,贺秀红,刘晓燕,等. 胎儿法洛四联症的产前超声诊断价值及体会[J].实用医学影像杂志,2020,21(1):92-93.
    [9]
    孟庆福. 不同超声切面二维超声和三维超声STIC技术诊断胎儿法洛四联症的价值[J].河南医学研究,2019,28(11):2055-2056. doi: 10.3969/j.issn.1004-437X.2019.11.067
    [10]
    彭可雨,张洪,梁汉欢,等. CT 联合超声心动图在法洛四联症诊断中的应用价值[J].中国临床研究,2017,30(4):485-488.
    [11]
    莫钟玲,陈丽萍,王银,等. 超声诊断法洛四联症合并右肺动脉缺如1例[J].中国医学影像学杂志,2016,24(7):514. doi: 10.3969/j.issn.1005-5185.2016.07.010
    [12]
    查长松,黄月红,戚丽,等. 胎儿法洛四联症的超声心动图特征分析[J].实用医药杂志,2016,33(3):213216.
    [13]
    陈清华,陈华娟,彭软. 圆锥动脉干畸形产前超声诊断与误诊分析[J].放射学实践,2017,32(11):1196-1199.
    [14]
    林李梅,郑洪平,李晓云,等. 产前超声诊断胎儿心血管畸形与产后诊断结果对比分析[J].中国妇幼保健.,2018,33(16):3829-3831.
    [15]
    丁洁,施海建,梁喜. 产前超声对胎儿法洛四联症疾病谱的鉴别诊断[J].中国优生与遗传.,2017,25(11):111-113.
    [16]
    张维敏,仝志荣,刘金龙. 法洛四联症肺动脉形态学分析[J].国际心血管病杂志,2017,44(1):39-42. doi: 10.3969/j.issn.1673-6583.2017.01.010
  • Relative Articles

    [1] Xuemei CHEN, Pin GUO, Liufang CHUAN, Zi WANG, Xuejiao LI, Wenji HE. Evaluation of Cardiac Toxicity of Anthracyclines in Children with Acute Leukemia Based on Tei Index. Journal of Kunming Medical University, 2024, 45(2): 117-122.  doi: 10.12259/j.issn.2095-610X.S20240216
    [2] Zhenxing YUAN, Wenfei SUN, Weidong WANG. Relationship between hs-CRP,CCL2,CCL3 and Neonatal Bacterial Infection and Their Predictive Value for Efficacy. Journal of Kunming Medical University, 2024, 45(7): 119-125.  doi: 10.12259/j.issn.2095-610X.S20240718
    [3] Wenjuan SONG, Xuejuan MA, Yue SUN, Ying GU, Yujia YE, Shumo LI, Fei GE, Liping LIU, Yue ZHAO, Yu WANG. Evaluation of Cardiotoxicity in Trastuzumab Treatment of Breast Cancer Using Three-dimensional Speckle Tracking Echocardiography. Journal of Kunming Medical University, 2023, 44(2): 108-112.  doi: 10.12259/j.issn.2095-610X.S20230217
    [4] Shuishui PAN, Jinsong BAI, Chongxi LI, Zhiqiong AI, Bo TIAN, Changlei MU, Yihan LIU, Jun LIU. Influencing Factors of Echocardiographic Abnormalities in HIV/AIDS Patients. Journal of Kunming Medical University, 2023, 44(4): 148-153.  doi: 10.12259/j.issn.2095-610X.S20230422
    [5] Yiming TANG, Yu CHEN, Yiming LU, Xuemei ZHANG, Jiangli YIN. Efficacy of Targeted Nursing Mode in Patients with High Altitude Pulmonary Edema. Journal of Kunming Medical University, 2022, 43(4): 158-162.  doi: 10.12259/j.issn.2095-610X.S20220427
    [6] Linkun TA, Yanling HUANG, Jingqiu ZhANG, Yongping LU. Value of Different Sections of Echocardiography in the Diagnosis of Fetal Congenital Vascular Ring. Journal of Kunming Medical University, 2022, 43(6): 79-84.  doi: 10.12259/j.issn.2095-610X.S20220615
    [7] Juan ZHAO, Teng-can TU, Mei-jun YANG, Xiao-yong ZHANG, Wei PAN. Assessment of Early Coronary Artery Disease in Patients with Acute Coronary Syndrome. Journal of Kunming Medical University, 2021, 42(12): 47-50.  doi: 10.12259/j.issn.2095-610X.S20211219
    [8] Li-zheng WEI, Jie-qing MIN, Jin-run TIAN, Yan-jie CAO, Peng PAN, Peng WANG, Yun-juan YANG, Yun-jiao LUO. The Characteristics of Echocardiography in Acute Incomplete Kawasaki Disease among Infants and Young Children in Yunnan Province. Journal of Kunming Medical University, 2021, 42(9): 114-118.  doi: 10.12259/j.issn.2095-610X.S20210923
    [9] Chen Zhi Song , He Biao Hua , Zeng Yong Li , Yu Zhuo . Clinical Application of Transcatheter Closure in Patent Ductus Arteriosus under the Guidance of Transthoracic Echocardiography. Journal of Kunming Medical University, 2019, 40(03): 68-72.
    [10] Min Jie Qing , Tian Jin Run , Hong Wei , Wei Li Zheng , Cao Yan Jie , Wang Hua Ping . Echocardiography in Evaluating the Right Ventricle in Children with Funnel Chest Surgery. Journal of Kunming Medical University, 2019, 40(03): 116-119.
    [11] Ye Xue Qun , Nie Lei . . Journal of Kunming Medical University, 2017, 38(02): 95-98.
    [12] Luo Qing 祎. . Journal of Kunming Medical University,
    [13] Long Qiong Hua . . Journal of Kunming Medical University,
    [14] Zhu Min . . Journal of Kunming Medical University,
    [15] Song Wen Juan . . Journal of Kunming Medical University,
    [16] Min Jie Qing . . Journal of Kunming Medical University,
    [17] He Guang Lin . . Journal of Kunming Medical University,
    [18] . The Assessment of Left Ventricular Longitudinal Systolic Function in Patients with Type 2 Diabetes Mellitus by Ultrasound 2-dimensional Strain. Journal of Kunming Medical University,
    [19] . Application Value of Intraoperative Ultrasonography in Hepatobiliary Pancreatic Surgery. Journal of Kunming Medical University,
    [20] Li Hua Ping . . Journal of Kunming Medical University,
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(3)  / Tables(2)

    Article Metrics

    Article views (3389) PDF downloads(19) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return