Volume 44 Issue 9
Sep.  2023
Turn off MathJax
Article Contents
Cheng PAN, Rongshuang YAN, Derui FEI, Xingfei DAI, Qitang LI, Yujian MA, Ying ZHANG. Accuracy of Sub-axial Cervical Pedicle Screw Placement:A Systematic Review with the Meta-analysis Comparing Free-hand and Assistant Techniques[J]. Journal of Kunming Medical University, 2023, 44(9): 32-38. doi: 10.12259/j.issn.2095-610X.S20230910
Citation: Cheng PAN, Rongshuang YAN, Derui FEI, Xingfei DAI, Qitang LI, Yujian MA, Ying ZHANG. Accuracy of Sub-axial Cervical Pedicle Screw Placement:A Systematic Review with the Meta-analysis Comparing Free-hand and Assistant Techniques[J]. Journal of Kunming Medical University, 2023, 44(9): 32-38. doi: 10.12259/j.issn.2095-610X.S20230910

Accuracy of Sub-axial Cervical Pedicle Screw Placement:A Systematic Review with the Meta-analysis Comparing Free-hand and Assistant Techniques

doi: 10.12259/j.issn.2095-610X.S20230910
  • Received Date: 2023-04-01
    Available Online: 2023-09-22
  • Publish Date: 2023-09-30
  •   Objective  To systematically compare the accuracy, direction of pedicle screw perforation, and screw-related complications of sub-axial cervical pedicle screw (sCPS) placement with and without assistant techniques.  Methods  A total of 26 studies involving 1697 patients and 6654 screws were included. Medline, Embase, and Cochrane databases were searched to collect the high-quality English literature on the accuracy of cervical pedicle screw (CPS) placement using different screw placement techniques from 2010.1 to 2022.12. Literature was screened according to the inclusion criteria, data was extracted, and a meta-analysis was performed using RevMan 5.4.   Results  The meta-analysis showed that assistant techniques had a higher accuracy rate for sCPS placement. Perforation of the lateral wall of the pedicle was more common than the medial wall, and free-hand screw placement was more common in the superior wall than the inferior wall. There was no statistically significant difference in the perforation rate between the superior and inferior walls with assistant techniques.   Conclusion  1. Assistant techniques has a higher accuracy rate for sCPS placement than free-hand techniques. 2. Perforation of the lateral and inferior walls of the pedicle is more common than perforation of the medial and superior walls. 3. A unified evaluation standard is needed for assessing the accuracy of sCPS placement. 4. Different assistant screw placement techniques have their own advantages and disadvantages, and should be selected according to the actual conditions.
  • loading
  • [1]
    Abumi K,Itoh H,Taneichi H,et al. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: Description of the techniques and preliminary report[J]. Journal of Spinal Disorders,1994,7(1):19-28. doi: 10.1097/00002517-199407010-00003
    [2]
    Abumi K,Shono Y,Ito M,et al. Complications of pedicle screw fixation in reconstructive surgery of the cervical spine[J]. Spine,2000,25(8):962969.
    [3]
    Kotani Y,Cunningham B W,Abumi K,et al. Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine[J]. Spine (Phila Pa,1976,),1994,19(22):2529-2539.
    [4]
    Jo D J,Seo E M,Kim K T,et al. Cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy[J]. J Korean Neurosurg Soc,2012,52(5):459-465. doi: 10.3340/jkns.2012.52.5.459
    [5]
    Lee S H,Kim K T,Abumi K,et al. Cervical pedicle screw placement using the "key slot technique": The feasibility and learning curve[J]. J Spinal Disord Tech,2012,25(8):415-421. doi: 10.1097/BSD.0b013e3182309657
    [6]
    Tofuku K,Koga H,Komiya S. Cervical pedicle screw insertion using a gutter entry point at the transitional area between the lateral mass and lamina[J]. Eur Spine J,2012,21(2):353-358. doi: 10.1007/s00586-011-1969-1
    [7]
    Wang Y,Xie J,Yang Z,et al. Computed tomography assessment of lateral pedicle wall perforation by free-hand subaxial cervical pedicle screw placement[J]. Arch Orthop Trauma Surg,2013,133(7):901-909. doi: 10.1007/s00402-013-1752-3
    [8]
    Liu J,Li Y,Wu Y,et al. A novel method of cervical pedicle screw placement from C3 to C5 and its clinical applications[J]. Spine (Phila Pa,1976,),2013,38(8):E504-E512.
    [9]
    Hojo Y,Ito M,Suda K,et al. A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws[J]. Eur Spine J,2014,23(10):2166-2174. doi: 10.1007/s00586-014-3470-0
    [10]
    Mahesh B,Upendra B,Mahan RS. The medial cortical pedicle screw-a new technique for cervical pedicle screw placement with partial drilling of medial cortex[J]. Spine J,2014,14(2):371-380. doi: 10.1016/j.spinee.2013.09.033
    [11]
    Park J H,Jeon S R,Roh S W,et al. The safety and accuracy of freehand pedicle screw placement in the subaxial cervical spine: A series of 45 consecutive patients[J]. Spine (Phila Pa,1976,),2014,39(4):280-285.
    [12]
    Lee JH,Choi BK,Han IH,et al. Cervical sedicle screw placement using medial funnel technique[J]. Korean J Spine,2017,14(3):84-88. doi: 10.14245/kjs.2017.14.3.84
    [13]
    Liu B,Liu X,Shen X,et al. The "slide technique"-a novel free-hand method of subaxial cervical pedicle screw placement[J]. BMC Musculoskelet Disord,2020,21(1):399. doi: 10.1186/s12891-020-03420-0
    [14]
    Hey H W D,Zhuo W H,Tan Y H J,et al. Accuracy of freehand pedicle screws versus lateral mass screws in the subaxial cervical spine[J]. Spine Deform,2020,8(5):1049-1058. doi: 10.1007/s43390-020-00119-z
    [15]
    Garg B,Mehta N. Safety and feasibility of cervical pedicle screw insertion in pediatric subaxial cervical spine without navigation: A retrospective cohort study[J]. J Pediatr Orthop,2021,41(2):119-126. doi: 10.1097/BPO.0000000000001694
    [16]
    V Rajan V,Kamath V,Shetty A P,et al. Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine[J]. Indian J Orthop,2010,44(2):163-168. doi: 10.4103/0019-5413.62083
    [17]
    Zhang H L,Zhou D S,Jiang Z S. Analysis of accuracy of computer-assisted navigation in cervical pedicle screw installation[J]. Orthop Surg,2011,3(1):52-56. doi: 10.1111/j.1757-7861.2010.00110.x
    [18]
    Shimokawa N,Takami T. Surgical safety of cervical pedicle screw placement with computer navigation system[J]. Neurosurg Rev,2017,40(2):251-258. doi: 10.1007/s10143-016-0757-0
    [19]
    Uehara M,Takahashi J,Ikegami S,et al. Screw perforation rates in 359 consecutive patients receiving computer-guided pedicle screw insertion along the cervical to lumbar spine[J]. Eur Spine J,2017,26(11):2858-2864. doi: 10.1007/s00586-016-4843-3
    [20]
    Shi H,Zhu L,Ma J,et al. The accuracy of a novel pedicle screw insertion technique assisted by a special angular scale in the subaxial cervical spine using lateral mass as a reference marker[J]. J Orthop Surg Res,2020,15(1):551. doi: 10.1186/s13018-020-02054-1
    [21]
    Rajasekaran S,Kanna P R,Shetty A P. Safety of cervical pedicle screw insertion in children: A clinicoradiological evaluation of computer-assisted insertion of 51 cervical pedicle screws including 28 subaxial pedicle screws in 16 children[J]. Spine (Phila Pa,1976,),2012,37(4):E216-E223.
    [22]
    Takahata M,Yamada K,Akira I,et al. A novel technique of cervical pedicle screw placement with a pilot screw under the guidance of intraoperative 3D imaging from C-arm cone-beam CT without navigation for safe and accurate insertion[J]. Eur Spine J,2018,27(11):2754-2762. doi: 10.1007/s00586-018-5706-x
    [23]
    Chachan S,Bin Abd Razak H R,Loo W L,et al. Cervical pedicle screw instrumentation is more reliable with O-arm-based 3D navigation: Analysis of cervical pedicle screw placement accuracy with O-arm-based 3D navigation[J]. Eur Spine J,2018,27(11):2729-2736. doi: 10.1007/s00586-018-5585-1
    [24]
    Fujita R,Oda I,Takeuchi H,et al. Accuracy of pedicle screw placement using patient-specific template guide system[J]. Orthop Sci,2022,27(2):348-354. doi: 10.1016/j.jos.2021.01.007
    [25]
    Kisinde S,Hu X,Hesselbacher S,et al. Robotic-guided placement of cervical pedicle screws: Feasibility and accuracy[J]. Eur Spine J,2022,31(3):693-701. doi: 10.1007/s00586-022-07110-4
    [26]
    Ishikawa Y,Kanemura T,Yoshida G,et al. Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: A retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement[J]. Neurosurg Spine,2010,13(5):606-611. doi: 10.3171/2010.5.SPINE09993
    [27]
    Liu Y J,Tian W,Liu B,et al. Comparison of the clinical accuracy of cervical (C2-C7) pedicle screw insertion assisted by fluoroscopy,computed tomography-based navigation,and intraoperative three-dimensional C-arm navigation[J]. Chin Med J (Engl),2010,123(21):2995-2998.
    [28]
    Nakashima H,Yukawa Y,Imagama S,et al. Complications of cervical pedicle screw fixation for nontraumatic lesions: A multicenter study of 84 patients[J]. Neurosurg Spine,2012,16(3):238-247. doi: 10.3171/2011.11.SPINE11102
    [29]
    Yoshii T,Hirai T,Sakai K,et al. Cervical pedicle screw placement using intraoperative computed tomography imaging with a mobile scanner gantry[J]. Eur Spine J,2016,25(6):1690-1697. doi: 10.1007/s00586-016-4508-2
  • Relative Articles

    [1] Tao CHEN, Tingrui WANG, Huanxiong CHEN, Kaizhong ZHU, Zhenhao ZHONG, Zhibin MENG. Clinical Study of Cervical Spondylotic Myelopathy Treated by Single Door Laminoplasty. Journal of Kunming Medical University, 2023, 44(6): 47-53.  doi: 10.12259/j.issn.2095-610X.S20230602
    [2] You-deng PU, Jun-yu YANG, Zhao-wen ZHOU, Hong DUAN, Qi-zeng SUN, Xiong JIN. Clinical Effects of Posterior Decompression Combined with Unilateral Fixation in Treatment of Single-segmentalcervical Spondylotic Radiculopathy. Journal of Kunming Medical University, 2021, 42(2): 75-80.  doi: 10.12259/j.issn.2095-610X.S20210230
    [3] Hu Xing Xi , Duan Hao , Zhong Zong Yu , He Fei . . Journal of Kunming Medical University, 2020, 41(05): 114-119.
    [4] Zhang Ying , Lu Yu , Zhao Zhi , Li Tao , Bi Ni , Shi Zhi Yue , Wang Ying Song , Jie Jing Ming , Song Yue Ming , Chang Li Tao , Guan Shuai , Tang Lin Bo . . Journal of Kunming Medical University, 2019, 40(11): 63-68.
    [5] Mo Jing , Zhang Ming Zhu . . Journal of Kunming Medical University, 2019, 40(10): 21-26.
    [6] Chen Tai Bang , Lu Sheng , Shi Jun Zhen , Shi Rong Mao , Liang Jin Long . Comparison of the Effects of Minimally Invasive Percutaneous Pedicle Screw Fixation and Conventional Open Spinal Internal Fixation on Type A3 Thoracolumbar Vertebra Fracture. Journal of Kunming Medical University, 2019, 40(03): 58-62.
    [7] Zhang Guo Zhi , Deng Yong Cheng , Lu Xiao Tao . . Journal of Kunming Medical University, 2018, 39(09): 56-61.
    [8] Xu Wei Nan , Xu Ying Kun , Cao Zhen Di . A Retrospective Analysis of General ICU Nosocomial Infection. Journal of Kunming Medical University, 2017, 38(06): 40-43.
    [9] Liang Yue Wei , Zhang Fan , Li Quan , Zhao Xue Ling . Early Effect of Zero-P VA In Cervical Spondylotic Myelopathy. Journal of Kunming Medical University, 2017, 38(06): 113-117.
    [10] Zhang Jian , Zhao Yang Xue , Li De Cheng , Zhao Jiang , Zhao Yu , Bai Rong . Clinical Effect of Zina and Sextant Pedicle Screw System on Thoracolumbar Fracture. Journal of Kunming Medical University, 2017, 38(01): 117-120.
    [11] Zhao Liang . . Journal of Kunming Medical University,
    [12] Tang Xiang Hui . . Journal of Kunming Medical University,
    [13] Li Shao Long . . Journal of Kunming Medical University,
    [14] Liang Zheng Zhong . . Journal of Kunming Medical University,
    [15] Ma Yun Bing . . Journal of Kunming Medical University,
    [16] Ji Lin Song . Transpedicle Screw Fixation in Treatment of Atlantoaxial Instability and Dislocation after Trauma. Journal of Kunming Medical University,
    [17] Duan Hong . Treatment of Thoracolumbar Burst Fracture with Transpedicular Bone Grafting Technique. Journal of Kunming Medical University,
    [18] . One-step Posterior Spinal Screw Fixation of Whole Pedicle of Vertebral Arch in Treatment of Sever Scoliosis. Journal of Kunming Medical University,
    [19] . . Journal of Kunming Medical University,
    [20] . . Journal of Kunming Medical University,
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(8)  / Tables(1)

    Article Metrics

    Article views (1132) PDF downloads(22) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return